    • DirkZ from Belgium 03 10 2013, 12:11 AM Report Spam
      Q91 (which view to select to create a baseline)
      answer is C : "admin"

      http://www.vmware.com/pdf/vsp_vum_40_admin_guide.pdf :
      Creating Baselines
      You can create patch and upgrade baselines to meet the needs of your specific deployment by using the
      New Baseline wizard. Creating additional, customized baselines allows patches to be grouped into logical sets.
      You create baselines in the Update Manager Client Administrator’s view.

    • DirkZ from Belgium 03 09 2013, 11:49 PM Report Spam
      Q73 is D: "verify and update system ROM" (before adding a processor)
      From HP Support:
      Advisory: SYSTEM ROM UPGRADE RECOMMENDED Before Adding Processors to Some ProLiant Servers or the System 05 Stop Responding During Power-On Self-Test (POST) with an "805-Unsupported Processor Detected" Message
    • Mohammed Ali from Bahrain 03 07 2013, 1:36 PM Report Spam
      I revised this dump and passed the exam today. I can say most of questions are from this dump but I'm not sure about the whole dump answers whether correct or not. I scored 72
    • xxxx from Unknown 03 06 2013, 11:08 AM Report Spam
      A have uploaded new dump with this questions but I have changed many answers.
      Please, review it. I didn`t try to pass the exam with it
    • Daulex from Unknown 03 06 2013, 10:09 AM Report Spam
      Did you use our correction from this comments ?
    • josh00b from Unknown 03 06 2013, 10:06 AM Report Spam
      Yes Daulex, all questions of dump are in the real exam,
      I passed this exam yesterday (failded) because many answers are wrong
    • Teemo from Cyprus 03 05 2013, 10:41 PM Report Spam
      Question 152 I think the answer is C

      You may remove and replace a disk from these hot-swap storage systems after checking that the Safe to Remove status indicates “Yes” for the drive to be replaced. ( copied from "P4000 SAN Solution User Guide " Page 46)
      http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c03035314/c03035314.pdf

    • xxxx from Unknown 03 05 2013, 2:57 PM Report Spam
      q17 is D
    • xxxx from Unknown 03 05 2013, 2:56 PM Report Spam
      Also:
      q132: D
      q146: A, E
      q149: C
      q152: A
      q157:B
    • Daulex from Unknown 03 05 2013, 10:52 AM Report Spam
      Q114. I think answer is C
      The HP CTO (Configure to Order) Program is designed to provide customers with a production of equipment manufactured tailor-made to their needs.
      Optimized Care Optimized Care Package: Supports maintaining servers at optimum performance availability HP ProLiant Server Hardware Installation
    • Daulex from Unknown 03 05 2013, 10:43 AM Report Spam
      Q112. Answers A, B are correct,. But can someone explain why D. For FlexFabric is "Maximum transmission unit (MTU) of up to 9216 bytes (jumbo frames)"
    • Daulex from Unknown 03 05 2013, 9:56 AM Report Spam
      Q96. Answer was B, but I think is D
      Answer was B, but I think is D

      Disaster Tolerance: Is some cluster features
      Disaster Recovery: You need to have everything on another site. It is replication features
      Business Continuity: Is Disaster Recovey + some software features.
      System Recovery: Recovery sistem prom bacup.

    • Daulex from Unknown 03 05 2013, 9:28 AM Report Spam
      Q.86. Answer A is 100 % true. But answer D as I know is not.
      "vcutil -a" command only has "version, update, report, discover" option.
      Command vcsu has that option, Syntax: "vcsu -a configbackup …"
      So there is just one answer A
    • Daulex from Unknown 03 05 2013, 9:09 AM Report Spam
      Q80. Is tricky one. Question is about "IT infrastructure security management". So probably answers are B,C but not to use VLAN1 is also very important …
    • SeriouslyPlayful from Cyprus 03 05 2013, 9:03 AM Report Spam
      Using HP Agentless Management, which components offer pre-failure alerting?
      Correct Answer is : Memory

      Answer is in this link in the first video:
      http://h30507.www3.hp.com/t5/Coffee-Coaching-HP-and-Microsoft/HP-ProLiant-Gen8-Agentless-Management-Overview/ba-p/108579

      http://www.youtube.com/watch?v=XDCBd_NeOuY&feature=player_embedded

    • josh00b from Unknown 03 04 2013, 2:55 PM Report Spam
      Q 90: My answer are C "HP SUM" (not B)
      Because the Active Health System collects data from iLO 4 itself, System ROM, Smart Array, NIC, and power supply firmware, hardware components, and optional OS agents. It collects approximately 1,600 unique data items
      http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03207602/c03207602.pdf P
    • seriouslyplayful from Cyprus 03 04 2013, 11:06 AM Report Spam
      After a power failure, how long will the data be retained on the cache of an FBWC of a Smart Array Controller
      Correct answer is :indefinitely
      The HP flash-backed write-cache (FBWC) system offers important advantages over battery-backed write-cache (BBWC) systems. HP designed the FBWC with NAND1 flash devices so that power is not required to retain cache data. There is no longer a 48-hour battery life limitation and the data will be posted to the disk drive the next time you power up the server. HP has engineered the FBWC to function with long-life super-capacitors (Super-caps) instead of a battery. The Super-cap is only used to power the FBWC system during data backup. The result is that the FBWC retains cache data regardless of server power states and you can adjust maintenance and replacement schedules to accommodate the longer Super-cap lifecycle. Figure 1-1 displays the FBWC module and the Super-cap housing.

      http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02231971/c02231971.pdf

    • Serge from Georgia 03 04 2013, 11:01 AM Report Spam
      Questions matched but still many wrong answers in this vce. I only got 68%
    • Daulex from Serbia 03 03 2013, 9:12 AM Report Spam
      Q17. FBWC is a flash based cache module that does not have battery limitation of how long it can retain what is written to the module. So answer is not E. 05be D
      Q24. Hot-asie = Racks face back to back. So answer is C
      Q33.Cold-asie = Racks face front to front. so answer is D
      Q60 Answer C not A
      Q73 Answer B not D. They did not say that they will put different processor..
      Q122. My answers are D, E
      Q134 My answers are B, F. Aluminium to avoid !!!!
      Q137 My answer B,D. As I understand P10000 is not proliant base
      Q146. I really not sure. I wiil use all HBA adapter, why to change MPIO setting.
      Q147. My answers is D, E Different voltage DIMM will work on higher voltage
      Q150. A, E 100%
      Q157. my answer is B
    • E100 from Kazakhstan 03 03 2013, 4:04 AM Report Spam
      People I have laid out the issues that will be on the exam. Just here all the time trying to post questions, but examination has three options. If you ever see one option then you're in luck.
    • oleole from Unknown 03 02 2013, 9:21 PM Report Spam
      150 Which services does HP offer to help you review current firmware levels and develop an appropriate management strategy? (Select two)
      • HP BladeSystem Firmware and Driver Gap Analysis
      • HP BladeSystem Firmware and Driver Update Process Review

      http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02225412/c02225412.pdf p8

    • crammer from Netherlands 03 01 2013, 10:44 AM Report Spam
      Great Dump, although some answers are wrong to my opinion.

      D